§ 18-21. Inspections.  


Latest version.
  • (a)

    Authority of building official; duties of permittee.

    (1)

    All construction or work for which a permit is required under this chapter shall be subject to inspection by the building official, and all such construction or work shall remain accessible and exposed for inspection purposes until approved by the building official. In addition, certain types of construction shall have continuous inspection as specified in section 18-22.

    (2)

    Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of this chapter or of any other ordinances. Inspections presuming to give authority to violate or cancel the provisions of this chapter or any other ordinances shall not be valid.

    (3)

    It shall be the duty of the permit applicant to cause the work to remain accessible and exposed for inspection purposes. Neither the building official nor the city shall be liable for expense entailed in the removal or replacement of any material required to allow inspection.

    (4)

    A survey of the lot may be required by the building official to verify that the structure is located in accordance with approved plans.

    (5)

    It shall be the duty of the permit applicant to install and maintain effective erosion and sediment control measures as specified in section 3307 of the International Building Code, as adopted by article II of this chapter. Should it be found that required erosion and sedimentation control measures have not been installed, the building official may refuse any inspection requests for work requiring inspections until such time as the site complies with the requirements of this chapter. Should it be found that the installed erosion and sediment control measures are ineffective or are not being maintained properly, the building official shall give notice to the permit holder. Subsequent inspections may be refused if the erosion and siltation control measures are ineffective, or not being maintained.

    (6)

    Before issuing a permit, the building official is authorized to examine or cause to be examined buildings, structures and sites for which an application has been filed.

    (b)

    Inspection requests. It shall be the duty of the person doing the work authorized by a permit to notify the building official that such work is ready for inspection. The building official may require that every request for inspection be filed at least one working day before such inspection is desired. Such request may be in writing or by telephone at the option of the building official.

    (c)

    Approval of successive portions of work, final inspection.

    (1)

    Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the building official. The building official, upon notification, shall make the requested inspections and shall either indicate that the portion of the construction or demolition is satisfactory as completed, or shall notify the permit holder or an agent of the permit holder wherein the construction or demolition fails to comply with this chapter. Any portions which do not comply shall not be covered or concealed until authorized by the building official.

    (2)

    There shall be a final inspection and approval of all buildings and structures when completed and ready for occupancy and use.

    (d)

    Required inspections.

    (1)

    Reinforcing steel or structural framework of any part of any building or structure shall not be covered or concealed without first obtaining the approval of the building official.

    (2)

    The building official, upon notification from the permit holder or permit holder's agent, shall make the following inspections and shall either approve that portion of the construction or demolition as completed or shall notify the permit holder or his agent wherein the construction fails to comply with this chapter:

    a.

    Footing or foundation inspection. A footing and foundation inspection shall be made after excavations for footings are complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place prior to inspection. All materials for the foundation shall be on the job; except, where concrete is ready-mixed in accordance with ASTM C94, the concrete need not be on the job. Where the foundation is to be constructed of approved treated wood, additional inspections may be required by the building official.

    b.

    Concrete slab or under-floor inspection. Concrete slab and under-floor inspections shall be made after all in-slab or under-floor reinforcing steel and building service equipment, conduit, piping accessories and other ancillary equipment items are in place but before any concrete is poured or floor sheathing installed, including the subfloor.

    c.

    Prebackfill. A prebackfill inspection shall be made after the foundation drainage and damproofing systems are complete and prior to backfilling.

    d.

    Rough-in inspection. A rough-in inspection shall be made after such work as framing, fireblocking, roof, piping, vents, ductwork, chimneys, wiring, etc., are in place and prior to concealment.

    e.

    Fire resistive rated assembly. A fire resistive rated assembly inspection shall be made at such time so as to verify that the construction of each fire resistive rated assembly is in accordance with its listing.

    f.

    Fire-resistant penetrations. An inspection shall be made of the firestopping or fireblocking of all penetrations, joints, etc., prior to concealment.

    g.

    Masonry throat inspection. For masonry fireplaces only, a masonry throat inspection shall be made after the firebox is built and the 1 st flue liner is in place. Construction of chimney may not continue until this inspection is approved.

    h.

    Utility connection inspections. Gas or electric service inspections shall be made prior to connection to the utility source. See section 18-11 of this article.

    i.

    Performance tests. Performance tests shall be conducted by the permit holder as required by this chapter, or as otherwise required by the building official.

    j.

    Demolition (basement and sewer) inspection. A basement and sewer inspection shall be made prior to the filling of the excavation and/or final grading of the property.

    k.

    Final inspection. A final inspection shall be made after all work under permit has been completed for the building, tenant space or demolition.

    (e)

    Other inspections. In addition to the inspections specified in subsection (d) of this section, the building official may make or require other inspections of any construction or demolition work to ascertain compliance with the provisions of this chapter or any other ordinances.

    (f)

    Building service equipment inspections. The requirements of this section shall not be considered to prohibit the operation of any building service equipment installed to replace existing building service equipment serving an occupied portion of the building if a request for inspection of such building service equipment has been filed with the building official not more than 48 hours after such replacement work is completed, and before any portion of such building service equipment is concealed by any permanent portion of the building.

    (g)

    Periodic inspections.

    (1)

    Elevators.

    a.

    Generally. All elevator equipment, vertical and inclined, shall be inspected as required by article IX of this chapter.

    b.

    Issuance of certificate of inspection. Where the inspections and tests indicate that the installation is in a safe operating condition, and, in the case of a new installation, conforms to this article, and the plans and specifications are filed, the building official shall issue a certificate of inspection to the owner of the elevator or the owner's agent. Such certificate shall be kept posted on the elevator. In the case of escalators and manlifts, such certificate shall be posted in a conspicuous place adjacent to the entrance of each escalator or manlift. No elevator, dumbwaiter, escalator, moving walk, workmen's hoist, manlift, chairlift or wheelchair lift which is covered by this chapter shall be used without such certificate. The owner, tenant, occupant or maintainer of property on which elevator equipment is being operated shall be responsible for the following use of such elevators: Freight elevators shall be ridden by the operator and freight handler persons only, and no-rider elevators shall not be ridden by persons.

    c.

    Revocation of certificate of inspection. Any certificate issued may be revoked if it is determined that the equipment is not in compliance with this chapter or that the fee for any required inspection or test has not been paid.

    d.

    Fees for tests and inspections. Fees for tests and inspections shall be as provided in section 18-20 of this chapter.

    e.

    Limited certificates. The building official may permit the temporary use of any equipment regulated by this chapter during the installation, alteration or repair, under the authority of a limited certificate issued for each class of service. Such limited certificate shall not be issued until the equipment has been tested under contract load and the car or counterweight safeties, terminal-stopping devices and other safety equipment has been tested and found to be safe for the class of service. Equipment operating under the authority of a limited certificate may be shut down or be subject to a double inspection fee if repairs or other requirements have not been completed in a timely manner.

    (2)

    Underground space.

    a.

    Generally. All new and existing underground spaces shall be inspected for structural adequacy at least once every five years. A report of the findings of such inspection shall be submitted to the building official to verify the conditions found on each occasion. The report shall be certified by a professional engineer registered to practice in the state. The report shall state that, in the opinion of the professional engineer, the underground space is safe and in such condition that it is capable of carrying the loads for which it was originally designed without any repairs or modifications, or what areas require repair before such certification can be given.

    b.

    Issuance of certificate of inspection. Where the inspection indicates that the installation is in a safe operating condition, and, in the case of a new installation, conforms to this chapter and this article, a certificate of inspection shall be issued to the owner or the owner's agent. Such certificate shall be maintained in an appropriate location.

    c.

    Revocation of certificate of inspection. Any certificate issued may be revoked if it is determined that the installation is not in compliance with this chapter or that the fee for certificate of inspection has not been paid.

    d.

    Fee for certificate of inspection. Fees for certificate of inspection shall be as provided in section 18-20 of this chapter.

    (3)

    Communication towers for television and radio transmission or reception.

    a.

    Generally. All new and existing structures shall be inspected for structural adequacy at least once every five years. A report of the findings of such inspection shall be submitted to the building official to verify the conditions found on each occasion. The report shall be certified by a professional engineer registered to practice in the state. The report shall state that, in the opinion of the professional engineer, the structure is safe and in such condition that it is capable of carrying the loads for which it was originally designed without any repairs or modifications, or what areas require repair before such certification can be given.

    b.

    Issuance of certificate of inspection. Where the inspection indicates that the installation is in a safe operating condition, and, in the case of a new installation, conforms to this chapter and this article, a certificate of inspection shall be issued to the owner or the owner's agent. Such certificate shall be maintained in an appropriate location.

    c.

    Revocation of certificate of inspection. Any certificate issued may be revoked if it is determined that the installation is not in compliance with this chapter or that the fee for certificate of inspection has not been paid.

    d.

    Fee for certificate of inspection. Fees for certificate of inspection shall be as provided in section 18-20 of this chapter.

    (4)

    Multilevel parking structures.

    a.

    Each owner of a multilevel parking station structure in its fifteenth year of age and every five years thereafter shall cause it to be inspected for structural adequacy by a registered professional engineer licensed in the state. A form known as the parking structure periodic inspection report shall be completed, sealed by the professional engineer who performed the inspection, and submitted to the city planning and development director to verify the conditions found. The parking structure periodic inspection report shall be submitted by June 1 of the sixteenth year and every five years thereafter.

    b.

    If the parking structure periodic inspection report certifies that all applicable structural elements are satisfactory or if the parking structure periodic inspection report certifies that there are some limited concerns and the professional engineer certifies that the structure has sound structural integrity, and should be considered safe for occupancy, then the city planning and development director shall issue a letter of acceptance. Such letters of acceptance shall expire five years from the date they are issued. Letters of acceptance may be revoked before expiration by the city planning and development director if the condition of the structure becomes unsafe.

    c.

    If the parking structure periodic inspection report indicates that the parking structure or part of the structure is unsafe or incapable of carrying the loads for which it was designed without repairs or modifications, the city planning and development director may require the owner to immediately vacate the entire structure or that part of the structure which is deemed unsafe. The structure or that part of the structure that is ordered vacated shall remain unused and unoccupied by either persons or vehicles until proper repairs or modifications render the structure safe and the opinion as required in subsection b. by the professional engineer is given. Once the required repairs or modifications have been completed and the professional engineer certifies that it has sound structural integrity and should be considered safe for occupancy, the city planning and development director shall issue a letter of acceptance as required in subsection b. and the structure shall be allowed to be occupied.

    d.

    No owner shall use or occupy a multilevel parking structure which structure is over the age of 16 years without a letter of acceptance as referred to in subsection b. above.

    e.

    Fees for the letter of acceptance shall be as provided in section 18-20 of this chapter.

(Ord. No. 040477, § 1, 8-12-04; Ord. No. 071193, § 1, 1-3-08; Ord. No. 120375, § 1, 5-24-12; Ord. No. 160454 , § A, 6-23-2016)