§ 88-430-06. EXTERIOR LIGHTING PLAN  


Latest version.
  • 88-430-06-A. WHEN REQUIRED

    An outdoor lighting plan must be submitted as part of any special use or development plan application. The lighting plan must be reviewed to determine whether the proposed outdoor lighting complies with the standards of this article.

    88-430-06-B. INFORMATION REQUIRED

    Outdoor lighting plans must include a photometric study and data on the types of lighting fixtures to be used. The photometric plan must include all of the following unless the city planning and development director determines that a thorough review and determination is possible without such information:

    1.

    scale drawing of the site with all outdoor lighting fixture locations identified;

    2.

    fixture specifications indicating the type of fixture, height, shielding, luminaire type and wattage;

    3.

    lamp type and size;

    4.

    a point-by-point illumination array for off-street parking areas and other vehicular use areas and along the property lines. The point-by-point array must indicate site illumination at (minimum) 10-foot intervals along the property line and at 20-foot intervals on the interior of the site.

    88-430-06-C. CERTIFICATION REQUIRED

    Prior to issuance of a final certificate of occupancy, a sealed letter by a licensed engineer shall be submitted, stating that photometries on the site comply with the approved photometric plan.