Kansas City |
Zoning and Development Code |
Appendix 100 SERIES. BASE ZONING DISTRICTS |
Appendix 88-110. RESIDENTIAL DISTRICTS |
§ 88-110-06. LOT AND BUILDING STANDARDS
88-110-06-A. GENERAL
This section establishes basic lot and building standards for all development in R districts. The standards vary based on zoning classification, building type and development type. These standards are not to be interpreted as a guarantee that allowed densities and development yields can be achieved on every lot. Other factors, such as off-street parking requirements, central water and wastewater service availability, and others may limit development more than these standards.
88-110-06-B. BASIC STANDARDS
All residential and nonresidential development in R districts must comply with the lot and building standards of Table 110-2, except as otherwise expressly provided by the building type-specific standards of 88-110-06-C. Nonresidential development in R districts must comply with the "conventional" development standards of Table 110-2. General exceptions to lot and building standards and rules for measuring compliance can be found in 88-820.
Table 110-2
Lot and Building Standards
R-80 R-10 R-7.5 R-6 R-5 R-2.5 R-1.5 R-0.75 R-0.5 R-0.3 CONVENTIONAL DEVELOPMENT Lot Size » Min. lot area (sq. ft.) 80,000 10,000 7,500 6,000 5,000 4,000 3,000 3,000 3,000 2,500 » Min. lot area per unit (sq. ft.) 80,000 10,000 7,500 6,000 5,000 2,500 1,500 750 500 300 » Min. lot width (ft.) 150 85 50 50 45 40 30 30 30 25 Front Setback » Minimum (% of lot depth) 25 25 25 25 25 25 15 15 15 15 » Min. garage (% of lot depth) 25 25 25 25 25 25 20 20 20 20 » Maximum required (ft.) 40 30 30 30 25 25 20 20 20 20 Rear Setback » Minimum (% of lot depth) 25 25 25 25 25 25 25 25 25 25 » Maximum required (ft.) 50 30 30 30 30 25 25 25 25 25 Side Setback » Min. each side (% lot width) 10 10 10 10 10 10 10 10 10 10 » Maximum required (ft.) 8 8 8 8 8 8 8 8 8 8 » Min. abutting street (ft.) 15 15 15 15 15 15 15 15 15 15 Height (ft.) » Maximum 35 35 35 35 35 40 45 60 164 235 OPEN SPACE DEVELOPMENT Overall Site » Min. open space (% of site) 30 30 30 30 30 30 30 30 30 30 » Min. lot area per unit (sq. ft.) 72,000 9,000 6,750 5,400 4,500 2,000 1,350 900 450 270 Lot Size » Min. lot area (sq. ft.) 12,000 7,500 6,000 5,000 3,750 3,000 2,500 2,500 2,500 2,500 » Min. lot width (ft.) 100 75 50 45 35 25 25 25 25 25 Front Setback » Minimum (% of lot depth) 20 15 15 15 15 15 15 15 15 15 » Min. garage (% of lot depth) 25 25 25 25 25 20 20 20 20 20 » Maximum required (ft.) 25 25 25 25 25 20 20 20 20 20 Rear Setback » Minimum (% of lot depth) 25 25 25 25 25 25 25 25 25 25 » Maximum required (ft.) 50 30 30 30 30 25 25 25 25 25 Side Setback » Min. each side (% lot width) 10 10 10 10 10 10 10 10 10 10 » Maximum required (ft.) 8 8 8 8 8 8 8 8 8 8 » Min. abutting street (ft.) 15 15 15 15 15 15 15 15 15 15 Height (ft.) » Maximum 35 35 35 35 35 50 60 60 120 200 CONSERVATION DEVELOPMENT Overall Site » Min. open space (% of site) 60 60 60 60 60 60 60 60 60 60 » Min. lot area per unit (sq. ft.) 64,000 8,000 6,000 4,800 4,000 2,000 1,200 800 400 240 Lot Size » Min. lot area (sq. ft.) 9,600 3,200 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 » Min. lot width (ft.) 85 50 45 35 30 25 25 25 25 25 Front Setback » Minimum (% of lot depth) 20 15 15 15 15 15 15 15 15 15 » Min. garage (% of lot depth) 25 25 25 25 25 20 20 20 20 20 » Maximum required (ft.) 25 25 25 25 25 20 20 20 20 20 Rear Setback » Minimum (% of lot depth) 25 25 25 25 25 25 25 25 25 25 » Maximum required (ft.) 50 30 30 30 30 25 25 25 25 25 Side Setback » Min. each side (% lot width) 10 10 10 10 10 10 10 10 10 10 » Maximum required (ft.) 8 8 8 8 8 8 8 8 8 8 » Min. abutting street (ft.) 15 15 15 15 15 15 15 15 15 15 Height (ft.) » Maximum 35 35 35 35 35 50 60 60 120 200 Required building setback shall be per this table or the platted building line, whichever is greater. Any residential unit having less than 350 sq. ft. per unit as of January 1, 2011, shall be considered conforming. 88-110-06-C. BUILDING-TYPE SPECIFIC STANDARDS
1.
ZERO LOT LINE HOUSES
Zero lot line houses are subject to the standards of 88-110-06-B ( Table 110-2), except as expressly modified by the following zero lot line house standards:
(a)
Zero lot line building arrangements require that the planning for all house locations be done at the same time. Because the exact location of each house is predetermined, greater flexibility in site planning is possible, while ensuring that neighborhood character is maintained.
(b)
The side setback on one side of the lot may be reduced to as little as zero. The zero-setback side may not abut a street or a lot that is not part of the zero lot line development. The minimum combined side setback requirements of 88-110-06-B apply on the "non-zero" side, which means that a lot with a zero side setback on one side must provide a setback equal to at least 20% of the lot width on the opposite side of the lot.
(c)
Eaves on the side of a house with a reduced setback may project over the abutting lot line only if a perpetual eave overhang easement at least 5 feet in width is provided on the lot abutting the zero lot line property line, which, with the exception of walls and/or fences, must be kept clear of structures. The easement must be shown on the plat and incorporated into each deed transferring title on the property.
(d)
When the zero lot line house's exterior wall or eaves are set back less than 2 feet from the abutting side lot line, a perpetual maintenance easement at least 5 feet in width must be provided on the lot abutting the zero lot line property line, which, with the exception of walls and/or fences, must be kept clear of structures. The easement must be shown on the plat and incorporated into each deed transferring title on the property. This provision is intended to ensure the ability to conduct maintenance and upkeep activities on the zero lot line house.
(e)
Windows or other openings that allow for visibility into the side yard of the lot abutting the zero-setback side lot are not allowed on zero lot line houses. Windows that do not allow visibility into the side yard of the abutting lot, such as clerestory windows or translucent windows, are allowed, subject to compliance with the building code.
2.
COTTAGE HOUSE
Cottage house developments are subject to the standards of 88-110-06-B (Table 110-2), except as expressly modified by the following cottage house development standards:
(a)
DEVELOPMENT SIZE
Cottage house developments must contain at least 4 and no more than 12 cottage houses. A development site may contain more than one cottage house development.
(b)
LOT SIZE
(1)
In the R-7.5, R-6 and R-5 districts the minimum required lot area per cottage unit is 50% of the minimum lot area per unit standard of 88-110-06-B (Table 110-2).
(2)
In the R-2.5 district the minimum required lot area per cottage unit is 75% of the minimum lot area per unit standard of 88-110-06-B (Table 110-2).
(3)
In the R-1.5, R-0.5 and R-0.3 districts the minimum lot area per unit standard of 88-110-06-B (Table 110-2) applies.
(c)
FLOOR AREA
(1)
The total floor area of each cottage may not exceed either 1.5 times the area of the main floor or 1,250 square feet, whichever is less. Attached garages are counted in the calculation of total floor area.
(2)
The maximum main floor area for cottages is 850 square feet. For the purposes of this calculation, the area of interior stairways may be allocated between floors served.
(d)
SETBACKS AND BUILDING SEPARATION
All structures within cottage house developments must be set back at least 15 feet from property lines abutting streets and 10 feet from other property lines along the outer perimeter of the cottage house development site. When vehicular access to a cottage housing development is from an alley, a 4-foot minimum rear setback is allowed. All buildings within the cottage house development must be separated by a minimum distance of 10 feet.
(e)
BUILDING HEIGHT
Cottage houses may not exceed 18 feet in height, except that pitched roofs with a minimum pitch of 6:12 may extend up to 25 feet in height. All parts of a roof above 18 feet in height must be pitched.
(f)
OPEN SPACE
Cottage house developments must include at least 200 square feet of common open space per cottage. At least 50% of the cottages in a cottage housing development must abut common open space and the common open space must have cottages abutting on at least 2 sides. All cottages must be located within 60 feet walking distance of the common open space.
Each cottage unit must have 150 square feet of private, contiguous, usable open space adjacent to each dwelling unit, for the exclusive use of the cottage resident. Such private open space must be oriented toward the common open space as much as possible, with no dimension less than 10 feet.
All cottages must have a roofed porch at least 80 square feet in area with a minimum dimension of 8 feet on any side.
3.
ATTACHED HOUSE
Attached houses are subject to the standards of 88-110-06-B ( Table 1102 ), except as expressly modified or supplemented by the following attached house standards.
(a)
The minimum lot width for an attached house is 18 feet.
(b)
The minimum lot area per unit requirements of 88-110-06-B ( Table 110-2 ) apply to attached house projects on a project-wide basis, meaning that the total area of the attached house site, including common areas comprising up to 20% of the overall site, may be counted as lot area. Common areas may include commonly owned open space, access drives and parking areas. Such common areas may also be included in setback calculations.
(c)
No side setback is required for common or abutting walls. The minimum total (combined) side setback standard of 88-110-06-B ( Table 110-2 ) applies along the sides of the building that do not have common or abutting walls.
(d)
Common or abutting walls must be shared for at least 50% of their length.
(e)
On corner lots, either the rear setback or side setback may be reduced to zero. However, the remaining side or rear setback must comply with the standards of 88-110-06-B ( Table 110-2 ).
(f)
The minimum total (combined) side setback standard of Section 88-110-06-B ( Table 110-2 ) applies along the sides of the building that do not have common or abutting walls.
(g)
The front facade of any attached house may not include more than 40% garage wall area.
(h)
Townhouse buildings may not contain more than 9 attached dwelling units.
4.
TWO-UNIT HOUSES AND SEMI-ATTACHED HOUSES ON CORNER LOTS
Under the conventional development option, two-unit houses and semi-attached houses are subject to the standards of Section 88-110-06-B ( Table 110-2 ). In approved open space or conservation developments two-unit houses and semi-attached houses are allowed on corner lots in all R districts except R-80. In R-10, R-7.5 and R-6 districts they are subject to the following additional standards.
(a)
Two-unit houses and semi-attached houses are allowed on corner lots in situations in which such building types would not otherwise be allowed because they can be designed so each unit is oriented towards a different street. This gives the two-unit house and the semi-attached house the overall appearance of a detached house when viewed from either street.
(b)
The corner lot must comply with the minimum lot area standard of the subject zoning district. No lot with less than 3,000 square feet of lot area may be used for the corner lot option.
(c)
Each dwelling unit within the two-unit house or semi-attached house must have its address and main entrance oriented towards a separate street frontage. Conversion of an existing detached house may provide one main entrance with internal access to both units.
5.
MULTI-UNIT HOUSE (includes Multiplex)
Multi-unit houses are subject to the standards of Section 88-110-06-B ( Table 110-2 ) except as expressly modified or supplemented by the following standards.
(a)
The street-facing façade of a multi-unit house may have only one visible entrance to the building. If the building is located on a corner lot, one building entrance may be visible from each street.
(b)
Visible building entrances must be clearly emphasized by any one of the following means:
(1)
covered porch or canopy;
(2)
transom and sidelight windows;
(3)
pilasters and pediment; or
(4)
other significant architectural treatment that emphasizes the entrance. (Simple trim around the doorway does not meet this standard.)
(c)
Patio-style doors, such as sliding glass doors, may not be used for main entrance doors.
(d)
A pedestrian circulation system must be provided that connects residential entrances to adjacent public rights-of-way and to parking areas and other on-site facilities.
(e)
Surface parking and parking within accessory structures must be located behind the front building line and otherwise concealed from view of abutting streets. Parking areas may not be located directly between the principal building and the street or within any required side setback area. Surface parking and the edge of the driveway from the right-of-way to any parking area or structure must be landscaped in accordance with 88-425-05 and 88-425-06.
(f)
The front facade of new multi-unit houses may not exceed 40 feet in width. Buildings may exceed this limitation if the street-facing plane of the building is broken into horizontal modules that comply with the following standards:
(1)
Each module must be no greater than 30 feet and no less than 10 feet in width and must be distinguished from adjacent modules by a change in the wall plane of at least 16 inches in depth. For buildings that are 3 or more stories in height, the width of the module may be increased to 40 feet.
(2)
Each module must have a corresponding change in the roofline.
(3)
Each module must be distinguished from the adjacent module by at least one of the following means:
a.
changes in material colors, types or textures;
b.
changes in the building and/or parapet height;
c.
changes in the architectural details such as decorative banding, reveals, stone, or tile accents;
d.
change in window pattern; and
e.
the use of balconies and recesses.
(g)
Architecture of the multi-unit house shall be designed in context with and reflect the predominant characteristics of other residential buildings within 500 feet of the exterior property lines of the multiunit house, in regard to scale, roof pitch, material, ingress/egress, and fenestration.
6.
COLONNADE BUILDING
A colonnade building is subject to the standards of 88-110-06-B ( Table 110-2 ) except as expressly modified or supplemented by the following standards.
a.
The street-facing facade of a colonnade building may have only one visible entrance to the building. If the building is located on a corner lot, one building entrance may be visible from each street.
b.
Visible building entrances must be clearly emphasized by any one of the following means:
1.
covered porch or canopy;
2.
transom and sidelight windows;
3.
pilasters and pediment; or
4.
other significant architectural treatment that emphasizes the entrance. (Simple trim around the doorway does not meet this standard.)
c.
Patio-style doors, such as sliding glass doors, may not be used for main entrance doors.
d.
A colonnade building must have porches available to each unit of the building. The porch must be a minimum of 5 feet in depth. On the main street-facing façade, porches must be located on each side of the main entrance, extending the full height of the building. If the building is on a corner lot, additional porches may be located on the side façade. Basement units are not required to have a porch.
e.
Cladding must be of brick, stone, or acceptable materials. Stucco may also be used on the upper stories of secondary facades.
f.
The main roof of a colonnade building must be flat, with a parapet that may include a hipped roof element.
g.
A pedestrian circulation system must be provided that connects residential entrances to adjacent public rights-of-way and to parking areas and other on-site facilities.
h.
Surface parking and parking within accessory structures must be located at the rear of the building and otherwise concealed from view of abutting streets. Parking areas may not be located directly between the principal building and the street or within any required side setback area. Surface parking area, and the edge of the driveway from the right-of-way to any parking area or structure, must be landscaped in accordance with 88-425-05 and 88-425-06.
i.
The front facade of a new colonnade building may not exceed 40 feet in width. Buildings may exceed this limitation if the street-facing plane of the building is broken into horizontal modules that comply with the following standards:
1.
Each module must be no greater than 30 feet and no less than 10 feet in width and must be distinguished from adjacent modules by a change in the wall plane of at least 16 inches in depth. For buildings that are 3 or more stories in height, the width of the module may be increased to 40 feet.
2.
Each module must have a corresponding change in the roofline.
3.
Each module must be distinguished from the adjacent module by at least one of the following means:
i.
changes in material colors, types or textures;
ii.
changes in the building and/or parapet height;
iii.
changes in the architectural details such as decorative banding, reveals, stone, or tile accents; and
iv.
change in window pattern.
j.
Architecture of the colonnade building shall be designed in context with and reflect the predominant characteristics of other residential buildings within 500 feet of the exterior property lines of the building, in regard to scale, roof pitch, material, ingress/egress, and fenestration.
k.
Colonnade buildings shall be designed in accordance with one of the following types:
1.
Classical Colossal Column Porch distinctive for Neoclassical styling featuring smooth or fluted Colossal columns of the Classical Order that rise the full height of the dark brick facade;
2.
Combined Column Porch featuring columns that extend more than one story in height and support a smaller column of different material and design or the reverse — columns that extend one story and support columns that extend upward for several stories;
3.
Square Brick Column Porch, a simpler version comprised of square brick columns;
4.
Transitional Enclosed Colonnade, this version retains the design of the original porch projections, but are enclosed and integrated with the interior living space.
l.
Courtyard Colonnaded Apartments: Colonnaded courtyard apartment are sets of three to seven buildings arranged in a U-shaped pattern around a courtyard with the courtyard opened to the street. The main facades of the buildings fact onto the courtyard.
7.
MULTI-UNIT BUILDING
Multi-unit buildings (i.e., buildings containing 3 or more dwelling units, other than multi-unit houses) are subject to the standards of 88-110-06-B ( Table 110-2 ) except as modified or supplemented by the following standards.
(a)
Visible building entrances to dwelling units on the ground floor must be clearly emphasized by any one of the following means:
(1)
covered porch or canopy;
(2)
transom and sidelight windows;
(3)
pilasters and pediment; or
(4)
other significant architectural treatment that emphasizes the entrance. (Simple trim around the doorway does not meet this standard.)
(b)
Patio-style doors, such as sliding glass doors, may not be used for main entrance doors.
(c)
A pedestrian circulation system must be provided that connects residential entrances to adjacent public rights-of-way and to parking areas and other on-site facilities.
(d)
Surface parking and parking within accessory structures must be located behind front building line or otherwise screened from view of abutting streets. Parking areas may not be located directly between the principal building and the street or within any required side setback area. Surface parking and the edge of the driveway from the right-of-way to any parking area or structure must be landscaped in accordance with 88-425-05 and 88-425-06.
(e)
Street-facing walls that are greater than 50 feet in length must be articulated with bays, projections, recesses or other design elements that effectively break-up the mass of the building.
(Ord. No. 120783, § 1, 10-4-2012; Ord. No. 120893, § 1, 11-8-2012; Ord. No. 130441, § 1, 7-11-2013; Ord. No. 150600, § A, 7-23-2015; Ord. No. 160759 , § 1, 10-20-2016; Ord. No. 170365 , § A, 5-25-2017)